R404A refrigerant is a blend of three HFCs (R125, R143a and R134a) introduced in the 1990s as a chlorine-free replacement for R502. It became the default choice for commercial and low-temperature refrigeration: supermarket freezer cabinets, cold rooms, ice machines and refrigerated trucks. A large amount of R404A equipment is still running in the UAE, so technicians and buyers still meet it every week.
Whether R404A is the right refrigerant for a given system depends on the system design, operating conditions, the manufacturer’s requirements and the regulations that apply. This article covers what R404A is, what it is made of, where it is used, how its pressure behaves, and what to check before you service, recharge, replace or buy it in the UAE.
What Is R404A Refrigerant?
R404A is a blended HFC refrigerant made from R125, R143a and R134a. It was developed to replace R502 and has been used mainly in commercial and low-temperature refrigeration, including freezers, cold rooms, supermarket cabinets and refrigerated transport. Its ozone depletion potential is zero, but its global warming potential is high (3,922 on most manufacturer SDS).
ASHRAE designates it R-404A and classifies it A1: lower toxicity and no flame propagation. It is a hydrofluorocarbon (HFC) blend, so it contains no chlorine and does not damage the ozone layer. However, a potent greenhouse gas, which is why the industry has been moving away from it.
It is a blend because no single HFC matched the capacity and pressure behaviour of R502 at low evaporating temperatures. Mixing R125, R143a and R134a in the right proportions gave equipment makers a refrigerant close enough to R502 that existing designs needed only limited changes. R404A behaves almost like a single-component refrigerant, with a very small temperature glide, which is one reason technicians found it easy to work with.
What Is R404A Made Of?
R404A is a mixture of three components, by weight:
| Component | Chemical name | Share by weight | Role in the blend |
| R125 | Pentafluoroethane | 44% | Non-flammable; keeps the blend from being flammable and supports capacity |
| R143a | 1,1,1-Trifluoroethane | 52% | Main contributor to low-temperature capacity; flammable on its own |
| R134a | 1,1,1,2-Tetrafluoroethane | 4% | Small fraction that generally helps oil miscibility and moderates pressure and discharge temperature |
The percentages are nominal. Manufacturers allow small tolerances, so the exact composition of a cylinder can vary slightly between producers. What matters in practice is that the components evaporate at different rates, which is why charging method matters (covered below).
Key Properties of R404A Refrigerant
The table below collects the properties most technicians ask about. Values differ slightly between sources because of measurement conditions and rounding, so ranges are shown where sources disagree. For design work, use the technical data sheet (TDS) from the specific manufacturer.
| Property | R404A |
| Refrigerant type | HFC blend (zeotropic, very low glide) |
| ASHRAE designation | R-404A |
| Composition (wt%) | R125 44% / R143a 52% / R134a 4% |
| ODP | 0 |
| GWP (100-year) | 3,922 (IPCC AR4 value used on most SDS); other assessment reports give different figures |
| ASHRAE safety classification | A1 (lower toxicity, no flame propagation) |
| Boiling point at 1.013 bar | About -46.2 to -46.5 °C, depending on source |
| Critical temperature | About 72 °C |
| Critical pressure | About 37.3 bar absolute (manufacturer TDS) |
| Molecular weight | About 97.6 g/mol |
| Temperature glide | Below 1 K (about 0.7 K in one manufacturer TDS) |
| Lubricant | Polyol ester (POE) oil |
| Cylinder colour code | Orange |
What Is R404A Refrigerant Used For?
R404A has been used mainly where low and medium evaporating temperatures are needed in commercial equipment. Typical applications include:
- Commercial freezers and reach-in freezer cabinets
- Cold rooms and cold-storage facilities
- Supermarket display cases and central rack systems
- Ice machines
- Refrigerated transport
- Food processing and some industrial low-temperature refrigeration
It is not suitable for every system. Equipment designed for another refrigerant should not be assumed compatible with R404A.

Commercial Freezers
R404A delivers good capacity at low evaporating temperatures, which made it a natural fit for freezer cabinets and blast or storage freezers. Many commercial freezer units sold in the UAE over the past two decades were designed around it. Check the unit nameplate for the refrigerant and charge before doing anything to the system.
Cold Storage
Cold rooms for food, pharmaceuticals and beverages use R404A in both chilled and frozen ranges. It works with a wide range of condensing units and, in the UAE’s high ambient temperatures, the system must be sized and set up so that condensing pressure and discharge temperature stay within compressor limits.
Supermarket Refrigeration
Display cases, freezer cabinets and multi-compressor racks were a core market for R404A. Older supermarket systems often still use it, while newer installations tend to use lower-GWP refrigerants or natural refrigerants such as CO2.
Ice Machines
Commercial ice machines, including flake and cube units used in hotels, restaurants and food service, historically used R404A. Many current models are now built for R290 or other lower-GWP options, but older units are still in service.
Transport Refrigeration
Refrigerated trucks and containers have used R404A because of its low-temperature performance. R452A was later developed with transport in mind, as it offers a lower GWP and a different discharge temperature profile.
Food Processing and Industrial Refrigeration
Smaller and mid-sized process cooling and freezing systems in food plants have used R404A where the design suits an HFC. Large industrial plants more often use ammonia or CO2.
Why Was R404A Widely Used in Commercial Refrigeration?
Several practical reasons explain its popularity:
- Low-temperature performance. It provides good capacity at evaporating temperatures typical of freezers.
- Pressure characteristics. Its pressures suited existing R502-era components, so equipment makers could adapt designs quickly.
- Safety classification. It is A1, which simplifies use in occupied commercial spaces.
- Availability and service familiarity. Technicians, wholesalers and OEMs all knew it, and parts, filter driers and service data were easy to find.
- Low glide. It behaves close to a pure fluid in evaporators and condensers.
This is the historical picture. It should be kept separate from the current one: with a GWP near 3,922, R404A is now under regulatory and commercial pressure in many markets, and new equipment increasingly uses other refrigerants.
R404A Refrigerant Pressure and Temperature
Like any refrigerant, R404A has a fixed relationship between saturation pressure and saturation temperature. Technicians use a pressure-temperature (PT) chart to convert gauge readings into evaporating and condensing temperatures. Always use the chart for the exact refrigerant and confirm whether it shows gauge or absolute pressure.
As a reference, one manufacturer TDS lists vapour pressures of about 2.49 bar absolute at -25 °C and 12.42 bar absolute at 25 °C. These are saturation values in absolute pressure. Real system pressures will differ with load and conditions.
Pressure readings alone do not tell you whether a system is correctly charged. Several factors change what you see on the gauges:
- Ambient temperature. In UAE summer conditions, high ambient air pushes condensing pressure up.
- Evaporating and condensing temperature. These set the low-side and high-side pressures.
- Indicates how much of the evaporator is being used and whether liquid may reach the compressor.
- Indicates liquid quality at the expansion device and whether the condenser and charge are performing properly.
This is why there is no single “normal” pressure for R404A. Pressures only mean something at stated operating conditions, so use them together with superheat, subcooling and the manufacturer’s data.
How Is R404A Refrigerant Charged?
R404A is a blend, so its components have different vapour pressures. If vapour is drawn from a cylinder, the lighter components leave first and the composition of what enters the system can shift. For this reason, R404A is charged as a liquid, from a cylinder configured for liquid withdrawal, and metered into the system in a controlled way. This keeps the blend composition correct.
General principles for qualified technicians:
- Follow the equipment manufacturer’s specified charge, usually shown on the nameplate.
- Recover any existing refrigerant with proper recovery equipment before opening the system.
- Evacuate with a suitable vacuum pump and verify with a micron gauge.
- Charge by weight using a scale, then fine-tune using superheat and subcooling as the manufacturer directs.
- Do not charge on pressure alone.
- Do not top up a system without finding and fixing the leak.
Refrigerant handling should be done by trained personnel. Venting to atmosphere is not acceptable, and recovered refrigerant should go to a licensed reclaim or disposal route.
R404A Refrigerant and Compressor Compatibility
Compatibility cannot be judged by the refrigerant name alone. The compressor, lubricant, expansion device, filter drier, seals and operating range all work together. A system designed for R404A is built around specific pressures and temperatures, and changing the refrigerant changes those conditions.
R404A systems use polyol ester (POE) lubricant, as stated in manufacturer technical data. POE is hygroscopic, meaning it absorbs moisture from air quickly, so systems must be kept sealed and properly evacuated. Mineral oil, which was used with R502, is not suitable for HFC blends on its own.
Before any refrigerant change, check the compressor manufacturer’s guidance, expansion valve type and rating, seals and gaskets, operating temperature range and the existing system design.
R404A Refrigerant Safety
R404A is classed A1 and is widely handled without special hazards, but it is still a pressurised liquefied gas. Sensible practice includes:
- Wear safety glasses and insulated gloves; liquid refrigerant can cause cold burns and frostbite on contact.
- Ventilate the work area. Refrigerant vapour is heavier than air and can displace oxygen in confined spaces such as cold rooms and plant rooms.
- Store cylinders upright or as marked, secured, away from heat and direct sun.
- Never heat a cylinder or overfill it. Follow the fill limits and use recovery cylinders rated for the refrigerant.
- Recover refrigerant instead of venting it.
- Read the SDS before handling and follow local requirements.
Environmental Impact of R404A
R404A has an ozone depletion potential (ODP) of zero because it contains no chlorine. Its global warming potential (GWP) is 3,922 on the IPCC AR4 basis used in most SDS, meaning one kilogram released has about 3,922 times the warming effect of one kilogram of CO2 over 100 years. Other assessment reports give different figures, so check which basis a document uses.
High-GWP refrigerants attract regulatory attention because refrigeration leaks add up. Under the Kigali Amendment to the Montreal Protocol, countries are phasing down HFC production and consumption, and several regions have added their own controls. The details differ by country and application, so it would be wrong to say R404A is banned everywhere. It is restricted or being phased down in some markets and still serviceable in others.
Is R404A Still Used in the UAE?
Yes, R404A is still present in many existing commercial refrigeration systems in the UAE, from supermarkets and food-service kitchens to cold-storage warehouses. Servicing and topping up existing equipment is a different matter from choosing a refrigerant for new equipment, and owners should treat them separately.
On the regulatory side, the UAE has ratified the Kigali Amendment. According to published industry reports, the UAE Ministry of Climate Change and Environment (MOCCAE) issued Decree No. 138 of 2023, which requires permits for activities such as manufacturing, importing, exporting and re-exporting HFCs, along with reporting obligations. Phase-down schedules and permit requirements can change, so confirm the current position directly with MOCCAE or your supplier before making decisions.
For system owners, the practical points are:
- Check the equipment manufacturer’s requirements before any recharge, replacement or retrofit.
- Confirm current UAE requirements for the refrigerant you plan to buy or use.
- Consider the long-term supply and cost of R404A when planning equipment replacement.
- Plan retrofits as engineering work, not as a simple gas swap.
R404A Refrigerant Alternatives
Alternatives are being considered because of R404A’s high GWP and the wider HFC phase-down. Most are HFC/HFO blends with a lower GWP. None should be treated as a universal drop-in: even where a manufacturer supports retrofit, the guidance usually calls for checks or adjustments.
| Refrigerant | Typical use | Approx. GWP (AR4) | Retrofit notes |
| R448A | Low- and medium-temperature commercial refrigeration | 1,387 | Manufacturer-supported for R404A retrofit in many systems; requires system evaluation |
| R449A | Low- and medium-temperature commercial refrigeration | 1,397 | Chemours guidance calls for expansion valve adjustment or a matching power element and compressor-maker checks |
| R407A | Medium-temperature, some low-temperature systems | 2,107 | Different capacity and glide profile; evaluate system first |
| R407F | Mainly medium-temperature systems | 1,825 | Different capacity and glide profile; evaluate system first |
| R452A | Transport refrigeration and some commercial systems | 2,140 | Developed with lower discharge temperatures in mind; verify compatibility |
Points that apply to most of these: they have higher glide than R404A, so charging and measurement practices need care; POE oil is generally used; and capacity, discharge temperature and expansion valve sizing need to be checked for each system. Chemours, for example, recommends checking elastomeric seals during retrofit and consulting the compressor manufacturer. Use manufacturer retrofit guidelines and the equipment maker’s approval, not general claims that one gas replaces another.
R404A vs Other Refrigerants
| Feature | R404A | R507A | R448A | R449A |
| Refrigerant type | HFC blend | HFC blend (R125/R143a, azeotropic) | HFC/HFO blend | HFC/HFO blend |
| Typical applications | Commercial low/medium temp | Commercial low temp | Commercial low/medium temp | Commercial low/medium temp |
| GWP (AR4) | 3,922 | About 3,985 | 1,387 | 1,397 |
| Low-temperature suitability | Good | Good | Good | Good |
| Retrofit considerations | Original design refrigerant | Similar to R404A; confirm with OEM | System evaluation required | System evaluation required |
The aim of this comparison is to show differences, not to name a winner. The right refrigerant depends on the equipment and the applicable rules.
How to Choose the Right R404A Refrigerant
For procurement teams and technicians buying R404A in the UAE, check the following before ordering:
- Confirm it is R404A (or the exact refrigerant your equipment specifies).
- Cylinder size. Match the size to the job and to your handling and recovery setup.
- Purity and specification. Ask for the grade and confirm it is virgin refrigerant.
- Brand and manufacturer. Know who produced it.
- Cylinder condition and seals. Look for damage, rust and tamper-evident sealing.
- Request the SDS and TDS.
- System compatibility. Check the nameplate and manufacturer requirements.
- Calculate the charge, plus allowance for recovery and losses.
- UAE requirements. Confirm that the supplier holds the required permits for HFCs.
R404A Refrigerant in UAE: What Buyers Should Know
Dubai and the wider UAE have a large HVAC/R market, driven by supermarkets, food-service, hospitality, logistics and cold-storage demand. That keeps a steady need for R404A gas for servicing existing commercial refrigeration equipment.
Cylinder sizes vary by brand and supplier, from small disposable cylinders to larger refillable ones, so ask the supplier which sizes they stock. For genuine product, buy from suppliers who can show documentation, keep cylinders sealed and can identify the manufacturer and batch. Counterfeit or mislabeled refrigerant is a known risk in the industry, and contaminated gas can damage compressors.
For larger jobs, ask about bulk supply, lead times and delivery. Confirm handling of cylinders during transport in UAE summer heat, and whether the supplier will take back empty or returnable cylinders. Compare quotes on the same basis: brand, purity, cylinder size, documentation and delivery terms, not price per kilogram alone.

Frequently Asked Questions About R404A Refrigerant
What is R404A refrigerant?
R404A is a blended HFC refrigerant made from R125, R143a and R134a. It has been used mainly in commercial and low-temperature refrigeration, such as freezers, cold rooms, supermarket cabinets, ice machines and refrigerated transport.
What is R404A refrigerant used for?
It is used in commercial refrigeration equipment that operates at low and medium temperatures. Common applications include commercial freezers, cold storage, supermarket refrigeration, ice machines and refrigerated transport.
Is R404A a gas or liquid?
Both. It is a liquefied gas stored in pressurised cylinders as a liquid, and it boils at about -46 °C at atmospheric pressure. Inside a refrigeration system it changes between liquid and vapour as it absorbs and rejects heat.
What is R404A made of?
R404A contains about 44% R125, 52% R143a and 4% R134a by weight.
Is R404A suitable for commercial freezers?
It has been widely used in commercial freezers and was designed for low-temperature duty. Suitability depends on the specific equipment, so follow the manufacturer’s specified refrigerant.
What oil is used with R404A?
POE (polyol ester) oil. Keep it sealed from air, because POE absorbs moisture quickly.
Does R404A have high GWP?
Yes. Its GWP is 3,922 on the IPCC AR4 basis used in most SDS. Its ODP is zero.
Can R404A be replaced with R448A?
R448A is marketed as an R404A replacement, but it is not automatically a drop-in for every system. Retrofit usually needs system evaluation and the equipment manufacturer’s guidance.
Is R404A still used in the UAE?
Yes, it is still present in many existing systems. Rules on HFC imports and use are evolving, so confirm current requirements with the relevant UAE authority or your supplier.
How do technicians charge R404A?
As a liquid, by weight, according to the system manufacturer’s specification, using suitable recovery, evacuation and charging equipment. Pressure alone is not a reliable basis for charging.
Final Takeaway
R404A is a non-flammable HFC blend of R125, R143a and R134a, built for commercial and low-temperature refrigeration. It has zero ozone depletion potential but a GWP of 3,922, and that is why regulators and equipment makers are moving to lower-GWP options. A system’s refrigerant should be chosen for its design, lubricant, components and operating conditions, and confirmed against manufacturer requirements and current regulations. Before charging, replacing or retrofitting, technicians should verify all of these first.